Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.920
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38631862

RESUMO

Intrathoracic needles are rarely used in clinical practice. They can migrate within the body, injure large blood vessels and other organs, and cause severe complications. We report an interesting case of intrathoracic needle removal using video-assisted thoracoscopic surgery. The needle was inserted under the left clavicle, penetrated the mediastinum, and migrated into the right thoracic cavity. Although pneumothorax developed during the disease course, no severe complications were observed. This rare case illustrates the course of needle migration from the mediastinum into the thoracic cavity. Prompt imaging and surgical removal of foreign bodies are necessary in cases of intrathoracic foreign bodies.


Assuntos
Corpos Estranhos , Migração de Corpo Estranho , Cavidade Torácica , Humanos , Mediastino , Resultado do Tratamento , Cavidade Torácica/cirurgia , Corpos Estranhos/cirurgia , Cirurgia Torácica Vídeoassistida/métodos , Migração de Corpo Estranho/cirurgia
2.
J Investig Med High Impact Case Rep ; 12: 23247096241238527, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38646799

RESUMO

Biliary endoprostheses are widely used in the treatment of biliary lithiasis, malignant and benign strictures, and occasionally in long-lasting biliary fistulas. They can be placed endoscopically during endoscopic retrograde cholangiopancreatography and radiologically (percutaneous) when the endoscopic route is not feasible. Complications associated with the endoscopic placement of biliary endoprostheses are well described in the literature, with migration being the most common. Intestinal obstruction is a rare complication associated with the migration of these devices. There are no reports in the literature of this complication occurring after percutaneous placement. We present a case of a patient who arrived at the emergency department with ileal obstruction secondary to the migration and concurrent embedding of a covered stent placed radiologically to treat a biliary leak after surgery. The patient underwent diagnostic laparoscopic and ileal resection, revealing a lithiasic concretion at the tip of the stent, causing the small bowel obstruction.


Assuntos
Migração de Corpo Estranho , Obstrução Intestinal , Stents , Humanos , Stents/efeitos adversos , Obstrução Intestinal/etiologia , Obstrução Intestinal/cirurgia , Migração de Corpo Estranho/cirurgia , Migração de Corpo Estranho/diagnóstico por imagem , Migração de Corpo Estranho/complicações , Masculino , Colangiopancreatografia Retrógrada Endoscópica , Feminino , Idoso , Laparoscopia , Intestino Delgado
3.
J Med Case Rep ; 18(1): 184, 2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38539178

RESUMO

BACKGROUND: Fractures of the clavicle are common injuries, which often require reduction and internal fixation. Although Kirschner pins have been commonly used to treat these fractures with good results, migration of these devices may result in severe internal lesions. CASE PRESENTATION: We report herein the case of 61-year-old man, who presented for intrapulmonary migration of a Kirschner pin, 25 years after closed reduction and fixation of a clavicle fracture. CONCLUSION: Migration of an osteosynthesis pin can be lethal. Patients with osteosynthesis pins, should have a regular follow, until the removal of the wires.


Assuntos
Migração de Corpo Estranho , Fraturas Ósseas , Masculino , Humanos , Pessoa de Meia-Idade , Clavícula/diagnóstico por imagem , Clavícula/cirurgia , Clavícula/lesões , Migração de Corpo Estranho/diagnóstico por imagem , Migração de Corpo Estranho/cirurgia , Fixação Interna de Fraturas , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Fios Ortopédicos/efeitos adversos
6.
Childs Nerv Syst ; 40(1): 19-25, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37857859

RESUMO

OBJECTIVE: The incidence of scrotal migration of a ventriculoperitoneal shunt (VPS) catheter is rare and may lead to life-threatening visceral complications. Management requires prompt removal of the migrated portion of the shunt and closure of the scrotal sac. We report an interesting case of a young child who presented with asymptomatic unilateral swelling of his scrotum secondary to a migrated VPS catheter. A repeat X-ray prior to his surgery to remove the migrated catheter showed that the entire length of the distal VPS catheter was back in the peritoneal cavity. In view of this unusual phenomenon, the case is discussed in corroboration with published literature. METHODS AND RESULTS: A systematic search of publications in the English language is performed in PubMed and Google Scholar. Our findings show that there are 49 reported cases (including our patient) of scrotal migration of shunt catheters in patients less than 18 years old. There is only 1 other case of spontaneous resolution of shunt catheter from the scrotum. Favoured management of choice is repositioning the distal shunt catheter back into the peritoneal cavity and herniotomy in the same setting, if possible. Overall, the literature suggests this is a shunt-related complication that has a good prognosis if intervention is timely. CONCLUSION: Scrotal migration of a VPS catheter is a rare but potentially life-threatening complication in children. Our case report highlights the role of updated preoperative imaging and the need for consistent long-term shunt surveillance in children.


Assuntos
Migração de Corpo Estranho , Hidrocefalia , Masculino , Criança , Humanos , Adolescente , Escroto/cirurgia , Derivação Ventriculoperitoneal/efeitos adversos , Peritônio , Remissão Espontânea , Hidrocefalia/cirurgia , Cateteres/efeitos adversos , Migração de Corpo Estranho/diagnóstico por imagem , Migração de Corpo Estranho/etiologia , Migração de Corpo Estranho/cirurgia
7.
Childs Nerv Syst ; 40(2): 587-591, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37855877

RESUMO

Intracardiac migration is a rare complication of ventriculoperitoneal shunt insertion. Only 15 cases have been reported, 7 of which were paediatric cases, treated with techniques including interventional radiography, open thoracotomies and direct extraction through the initial shunt incision. The authors report the youngest case of intracardiac shunt migration complicated by significant coiling and knotting within the cardiac chambers and pulmonary vasculature. Migration likely began when the SVC was pierced during initial shunt placement and progressed due to negative intrathoracic pressure. Extrusion was achieved combining thoracoscopic endoscopy, interventional fluoroscopy screening and a posterolateral neck incision with uncoiling of the shunt via a Seldinger guide wire. This offered a minimally invasive solution with rapid post-operative recovery.


Assuntos
Migração de Corpo Estranho , Derivação Ventriculoperitoneal , Humanos , Criança , Derivação Ventriculoperitoneal/efeitos adversos , Derivação Ventriculoperitoneal/métodos , Cateteres/efeitos adversos , Cateterismo , Migração de Corpo Estranho/diagnóstico por imagem , Migração de Corpo Estranho/etiologia , Migração de Corpo Estranho/cirurgia
10.
Rev Gastroenterol Peru ; 43(3): 273-276, 2023.
Artigo em Espanhol | MEDLINE | ID: mdl-37890854

RESUMO

This is a case report of a 47-year-old woman, carrier of an adjustable gastric band since 2018, that developed abdominal pain due to partial migration into the stomach. which was successfully removed endoscopically using Sohendra's lithotriptor.


Assuntos
Migração de Corpo Estranho , Gastroplastia , Feminino , Humanos , Pessoa de Meia-Idade , Dor Abdominal , Endoscopia , Migração de Corpo Estranho/diagnóstico , Migração de Corpo Estranho/cirurgia , Migração de Corpo Estranho/etiologia , Gastroplastia/efeitos adversos , Estômago
16.
Retin Cases Brief Rep ; 17(2): 170-172, 2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33731604

RESUMO

PURPOSE: To describe a novel office procedure that permits the repositioning of an Ozurdex implant from the anterior chamber back into the vitreous cavity. METHODS: Description of an office technique for Ozurdex repositioning using a 30-gauge needle. RESULTS: In both cases, the Ozurdex implant was successfully returned to the vitreous cavity. In Case 1, the patient's visual acuities 1 and 2 weeks after this were 20/70 and 20/40, respectively, and had no further complications. In Case 2, the patient returned 1 week later, with the implant remaining posterior and a visual acuity of 20/40. CONCLUSION: The success of this novel technique in these cases demonstrates the potential to avoid a surgical procedure in the event of Ozurdex implant migration to the anterior chamber, while at the same time allowing the Ozurdex implant to remain effective in the eye.


Assuntos
Migração de Corpo Estranho , Edema Macular , Humanos , Migração de Corpo Estranho/cirurgia , Edema Macular/complicações , Dexametasona , Glucocorticoides , Câmara Anterior/cirurgia , Administração de Consultório , Implantes de Medicamento
17.
Br J Neurosurg ; 37(5): 1358-1361, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33063544

RESUMO

BACKGROUND: Incidentally found intra-spinal bullets are extremely rare, and have never been reported in the literature. The aim of this study is to report a rare case of an asymptomatic migrating intra-spinal bullet, emphasizing the role of cultural context in history taking, and describing its surgical retrieval technique. CASE PRESENTATION: We discuss a case of a 10-years old boy with an incidentally discovered intra-spinal bullet opposite to the L5 vertebral level, who presented 3 months after the suspected initial insult. Following its migration to the L3/L4 level intraoperatively, the bullet was forced to spontaneously return to its preoperative position by reverse Trendelenburg Position, Valsalva maneuver and Intrathecal saline infusion, thus avoiding extending the previously performed laminectomy. CONCLUSION: The authors remind the readers that history is the cornerstone of the clinical practice, even in the most obscure cases. Many convoluted intra-operative situations could be resolved by utilizing basic anatomical and physiological principles.


Assuntos
Migração de Corpo Estranho , Ferimentos por Arma de Fogo , Masculino , Humanos , Criança , Migração de Corpo Estranho/diagnóstico por imagem , Migração de Corpo Estranho/cirurgia , Ferimentos por Arma de Fogo/diagnóstico por imagem , Ferimentos por Arma de Fogo/cirurgia , Coluna Vertebral/cirurgia , Laminectomia
20.
J Hand Surg Asian Pac Vol ; 27(5): 907-911, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36178419

RESUMO

A complication of Kirschner (K) wire fixation is the migration of the wire. We report a patient who had undergone fixation of a right clavicle fracture associated with acromioclavicular joint (ACJ) dislocation 15 years ago. He presented with features of pain and dysaesthesia in the right ulnar nerve dermatome on the movement of the neck and shoulder. Radiographic investigations showed a broken K-wire that had migrated to the lower brachial plexus. He underwent surgical removal of the K-wire and recovered uneventfully. We summarise the literature on K-wire migration reported following clavicle and ACJ injuries. Level of Evidence: Level V (Therapeutic).


Assuntos
Articulação Acromioclavicular , Plexo Braquial , Migração de Corpo Estranho , Fratura-Luxação , Masculino , Humanos , Fios Ortopédicos/efeitos adversos , Articulação Acromioclavicular/diagnóstico por imagem , Articulação Acromioclavicular/cirurgia , Migração de Corpo Estranho/diagnóstico por imagem , Migração de Corpo Estranho/etiologia , Migração de Corpo Estranho/cirurgia , Fratura-Luxação/diagnóstico por imagem , Fratura-Luxação/cirurgia , Fratura-Luxação/complicações , Plexo Braquial/diagnóstico por imagem , Plexo Braquial/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...